IIRC those have AKB so no pots to adjust. See if it is in
the service menu. WHENEVER you change anything write the
old setting down !!!

Press and hold MENU until the user menu disappears (5 - 10 sec.)
*The remote or the keyboard on the set can be used
Immediately press 9, 8, 7, 6, ENTER (this will bring up the service menu)
* On models with 10 buttons keyboard, without delay, press simultaneously ADJ. RIGHT and CH+

* On model with 6 button key board, without delay, press simultaneously VOL+ and CH -

Press and hold MENU until the menu disappears
The set should now be in the service menu mode.
To access most of the features selection 00 needs to be toggled from 0 to 1
After your adjustments 00 needs to be toggled from 1 to 0
To exit the service menu press ENTER

73 Zeno

Quote:
Originally Posted by Dreamsbeard View Post
Hello fellow CRT nut Zombies (its halloween so why not)

Just a quick question for you today ; I brought home a 1983 zenith system 3 console with a 9-214 main board (strange as I tought that was advance system 3 board aprox 1985). The problem is, I need to touch up the grayscale but I can't find the individual screen potentiometers.

Main screen and focus are on the flyback...but where are individual gun adjustment?

Thanks!