But the HV value itself isn't gonna change whether the filter cap is grounded to chassis or to B+. Remember, it's an RF ground either way (the spikes being filtered are RF).
With the cap grounded to B+, the DC across the cap will be lower by the B+ value. The HV itself willl be unchanged.
Last edited by old_coot88; 10-16-2016 at 12:55 PM.
|