Would the horizontal ringing also cause the reduced vertical. I'm still wondering if I hooked up the replacement vertical output transformer right. The Sams gives instructions in the parts list and they are confusing.
It says: Connect blue lead to transformer plate.
Connect green lead of transformer and Boosted B+ to brown lead of
yoke.
remove green lead from yoke from it's present terminal and connect
to red lead of transformer.
It doesn't say anything about where the yellow lead goes. I assume it still goes to the 340V.
Those instructions are confusing. Here are two parts of the schematic showing where all leads of the original transformer went and also where the brown wire off the yoke went.
The original green lead went to the brown lead of the yoke. The new instructions say do that as well as put the boosted B+ to this lead. If I read the schematic right, the original red lead is the boosted B+. That lead goes thru R76, R77, then thru a 2.2 med (R80) and onto pin 10 of CRT at 525V.
If I've got this transformer wired in wrong, could that be pulling down my B+? However if I disconnect all leads of the vert transformer, B+ is still pulled down.
|