This leads me to another question. I couldn't get a 200pf cap used in K6 the H. AFC couplet. So I'm guessing that a 220pf would work?
Also the 5000pf caps used in K1 Blanking, K6 Vertical Integrator, and K8 the CRT Isolation couplets will be replaced with 4700pf caps.
Also the 8000pf caps used in K2 Audio, and K3 Sync Coupling couplets will be replaced with a 8200pf cap.
Anybody see any problems with those subs?
Thanks.
Last edited by Crist Rigott; 06-25-2017 at 06:08 PM.
Reason: Changed 200pf to 220pf
|