Then by all means do as Electronic M suggested and check resistance from each lead of L1 to chassis ground. You may need to disconnect both L1 wires from the circuit to get an accurate reading.(as Tube TV said above my post)
I checked the filter choke with my ESR/LCR Meter (which also checks resistors and resistance loads) and the filter choke checks out within tolerance of the original specs given in the Sam's Folder, it checked at 27.7 Ohms and 1.69 Henries, which the original specs given in the Sam's Folder for the Choke is 32 Ohms and 1.5 Henries.

As for the individual leads checked to ground, one lead read 254 Ohms and the other lead measured infinite.