Quote:
Originally Posted by freakaftr8
Are the voltages off the 6JH6 1st IF correct? It's hard to read but c17 is tied to all those that goes to ground. is it shorted?
|
if 2nd if is down then 1st can't work
the 2nd gives the plate bias to the 1st
not sure what it is yet, Remember i have a CTC-16-XL.
almost the same as the 16, but different in quite a few ways.