I had a similar picture when a stray solder glob dropped across a connection and brought the negative voltage to about 25% of what it should have been. Basically the whole picture shrank, vertical was able to be adjusted to fill the screen, but horizontal showed the shrinkage. Also no sound. I finally found the shorted connection and everything was back to normal...for that set anyway.
|