View Single Post
  #38  
Old 04-17-2020, 05:51 PM
Donj Donj is offline
VideoKarma Member
 
Join Date: Feb 2019
Posts: 28
Another question. With all the interconnect wires coming out of the chassis, I failed to notice, until now, a somewhat random looking wire emerging through a non-factory looking hole on the rear of the chassis. No connector, in fact no exposed conductor. Tracing the wire to its source, I find it attached to the plate of the 6AL5 "clamper" tube. Now, the socket of this tube is enclosed in a screwed down metal shield so access for any reason would necessitate first removing the shield. I am wondering if this was added sometime in the set's life to enable plate voltages to be measured for service purposes..
Stupid question...Should I just leave it hanging out? Could leaving it there possibly introduce any instability due to the fact that it originates in a shielded part of the circuit?
Also, the 1/2 watt resistor that is also attached to pin 2 is reading high , about 2.3 meg should be 1.5 meg according to schematic was getting ready to change and just looked at the parts list to confirm the power rating. Parts list call for 3.9 meg. I suppose I should go with what's already there. I'm colour blind but wifey confirms its brown, green, green.
Attached Images
File Type: jpg v6bsm.jpg (43.9 KB, 17 views)
File Type: jpg wiresm.jpg (62.7 KB, 23 views)

Last edited by Donj; 04-17-2020 at 06:26 PM. Reason: one more question
Reply With Quote