That's not a bad TCON, that's a bad display. Remove one ribbon from the TCON to the display and run it with half a pic. If the picture is good, the disconnected side is bad. If it's the same, reconnect the ribbon and remove the other side.
If you can get half a good pic, let me know. There's a trick to "fixing" those.