View Single Post
  #15  
Old 09-03-2021, 06:24 PM
zeno's Avatar
zeno zeno is offline
VideoKarma Member
 
Join Date: Mar 2013
Location: New Hampshire
Posts: 4,918
True. I tend to assume OP hasnt had 40+ yrs in the entrails of a TV. So
I try to keep it simple & safe, one step at a time. In a perfect world
the OP, TV & me would be all in one place with a great parts stock &
the best of equipment. Without that its a challenge for all of us to help.

73 Zeno
LFOD !

Quote:
Originally Posted by Yamamaya42 View Post
the voltage on the plate cap CAN be measured, if IF it is unhooked from the HOT and there are NO horizontal pulses, it should be aprox the same that is going into the damper, the danger is that ANY horizontal pulses or feedback from the FBT can toast your meter, but if horizontal not running, and its unhooked, it's usually safe.
Reply With Quote