You really haven't given enough of the info someone would need to figure this out.
First of all don't go changing the tester to fit what you think the connection should be for this CRT. You will spoil it for other CRTs.
You haven't told what the CRT number is or what number CRT you chose in the table that you intend to use. Choosing a setup because some of the digits match is probably not good enough.
How about posting the schematic of the tester.
CRT testers don't put the same voltage on the tube as that when the tube is in use. The voltages are selected to give the proper reading on the tester.
For no raster you could just measure the voltages the monitor puts on the tube vs. what the monitor schematic indicates to determine if the CRT is functioning.
Yes you may need to get a HV probe.
|