View Single Post
  #222  
Old 12-07-2021, 03:20 PM
Kevin Kuehn's Avatar
Kevin Kuehn Kevin Kuehn is offline
Workin' Late Again
 
Join Date: Jan 2011
Location: WI
Posts: 3,976
Quote:
Originally Posted by vortalexfan View Post
I apologize for that, I've not worked on a TV that's this complicated before (the Meck TV I worked on was a lot Simpler than this and it just worked once I recapped it, it didn't have all of these weird complications that this Zenith has been having, and the funny thing is that the Meck TV was stored in harsher conditions than this Zenith was and it still worked without much issue after a full recap.)
I've got a couple dumb questions.

What DC voltage do measure from end to end of the 470 ohm R56?

And from what point have you been getting your B- or ground reference when taking DC voltage measurements? The reason I ask is that you're 245 B+ measured about 25 volts low, and also you mentioned measuring -22 volts at some point.
Reply With Quote