View Single Post
  #7  
Old 01-22-2022, 11:03 PM
YamahaFreak's Avatar
YamahaFreak YamahaFreak is offline
<-- CSXT 6038, EMD GP40-2
 
Join Date: Dec 2005
Location: TOO sunny Florida, USA
Posts: 580
Quote:
Originally Posted by zeno View Post
Blink codes aside usually its over current shut down due to a bad FBT.
Wega sets had LOTS of bad FBT's. If you need to change one
you often need a special tool to get the HV lead out of the FBT.
IIRC the HVSD did not monitor the power supply directly. It watched
for over voltage or over current on the FBT. Most common SD was caused by
cold joints on the vert IC.
Service tip is to monitor the 200V supply to the CRT & see if it pulses.
Also with the DGS unplugged monitor the current draw of the set.
Normal running amps is apx 750 ma. If it pulses above apx 1 amp
its over current SD, FBT or other load on the FBT

BTW the 24" Wega was a hot seller. Perfect size for many. Always ran
out of them in a few weeks & had to wait for the next build to
fill orders.

73 Zeno
LFOD !
Thanks much for this info. Question: what does DGS stand for? Is this the degauss circuit, or? I'm also probably going to reflow all potentially problematic solder joints just to see if that helps things. As things stand, that relay is the only sign of life, at least audibly. No static charge reaches the CRT face, nothing. Can I even get a replacement FBT for these sets anymore? Interesting to know about these being hot selling sets...must have been a lot of them made.
__________________
Sony Trinitron Fan
Reply With Quote