Posts: 3,976
You can try tying pin 7(grid) of V105 directly to pin 8(cathode). With the cathode and grid both at the same -85v it should cut-off the tube from conducting current and allow pin 6 (plate) to go positive. With the grid at -85 and -84 on the cathode it should be cut-off with no IF signal present. Check R120, R121 for correct resistance. Something needs to give.

Last edited by Kevin Kuehn; 08-13-2022 at 06:21 PM.