Quote:
Originally Posted by timmy View Post
C59 is 470pf I measured 410pf does ceramic caps go down in value? As for the vertical it does have 640v boost.
ceramic capacitors rarely ever go bad, and most in the set are 20% values unless otherwise listed, and it's very had to test in circuit unless you have a tester that was specifically made to test capacitors in circuit with leads that compensate, then a simple DVM will always give bad (deviated ) readings, especially with lower value capacitors because the length and position of the leads themselves used will skew the test results.

Notice the leads on this $1200 pro tester.
https://media.digikey.com/Photos/BK%...os/LCR-600.JPG

And yes, and mentioned before the vertical uses the 640v boost in 3 areas.

Vertical Height pot R17, Vertical linearity pot R18 and it also goes to C5 to R109 / C3.

Any problem here, and you would most likely lose sweep.
__________________
=^-^=