View Single Post
  #91  
Old 04-09-2023, 10:41 PM
Electronic M's Avatar
Electronic M Electronic M is offline
M is for Memory
 
Join Date: Jan 2011
Location: Pewaukee/Delafield Wi
Posts: 15,471
I am atomic! Lol. You can edit your posts if you want to there should be an edit button next to quote if you are reading this via a web browser.

It's encouraging that it was an external generator, but you can still get same false reassurance from an external generator if both the generator and scope have 3 prong power cords...Most test equipment that have 3 prong power tie the signal negative/ground to building ground and test equipment plugged into the same outlet can sometimes use that in lieu of the signal cable ground when it goes open.
__________________
Tom C.

Zenith: The quality stays in EVEN after the name falls off!
What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4
Reply With Quote