The Sams gives voltages for the 12” version but I used them as a reference anyway. The cathode is supposed to be 365v DC and I’ve got 345v. G2 should be 100v and I’ve got 210v. When I was fishing to see if I could find a place to check G1, I found a 0.1uf cap connected between the lead going to the CRT and a coil had broken off of its solder tab. Of course at that moment I had to go upstairs and shut down for the night but I’m hoping that solves the issue. We’ll see. I wonder if the loss of that cap in the circuit could have led to the G2 voltage doubling?
|