Changed out .22 capacitor for two paralleled .1 caps to make .2 for original value. This cap goes to the 6bg6 tube. I tried adding caps to the .035 cap which is on the left side of horizontal lin. coil. Made picture shrink horizontally. I didnt want that. So caps on both sides of horiz. lin. coil are .035 and .1 I might mess with the .1. Also there was a 100 ohm resistor that measured 228 ohms. picture is better but i need to tweak it more to the right the whole picture. Focus coil isnt cranked hard horizontally lookin like its all crooked now. I still have it cranked but not near as much.
|