View Single Post
  #132  
Old 07-27-2024, 04:38 AM
fumplet fumplet is offline
VideoKarma Member
 
Join Date: Apr 2023
Posts: 161
Focus coil is and isnt perfectly centered around tube neck depending on what im messing with. Trying to adjust yoke on tube and or taking tube out but cant due to tube socket getting stuck in yoke. Focus coil is slightly tilted horizontally but its tilted in the direction of which I want the picture to go or move I think but that could be just the yokes cap next to the focus coil causing the illusion of being tilted. Well if it is a leaky cap then it would have to be a mica one unless i have missed a paper cap. I have not removed the rectangular shield under chassis yet so if caps are hiding under there i will look. Notice the disc caps which have wax on them and they appear to be bubbly under the removed cover. Disc caps getting hot from going bad which everyone says they dont go bad hardly at all or is this ambient heat absorption. The heat baked 15k resistor measures 7.5k ohms so somethings parallel with it or it needs replaced. Also, under the video cover theres like 4 or 5 of 1k ohm resistors that are 1.2k and above in value with highest at 1.5k ohms. The Canohm resistor I suspect is also not too good and guessing this is the 6k ohm resistor and IM getting readings of 6.3k up to 35k ohms.
.
Attached Images
File Type: jpg Admiral 24c15 under video cover.jpg (78.2 KB, 24 views)
File Type: jpg Amiral 24c15 under video cover.jpg (73.6 KB, 20 views)

Last edited by fumplet; 07-27-2024 at 08:09 AM.
Reply With Quote