Quote:
Originally Posted by Yamamaya42
Could perhaps that 56pf cap in the yoke on the horizontal core be a source of this problem?
If it were open/shorted, throwing the entire horizontal section out of tune, and thus, upsetting the balance of the power supply?
|
I disconnected one end of that mica capacitor and measured 70pf so I replaced it. No change. Having a closer look at the FP electrolytics which I pried open and re stuffed with Nichicon radials. Ugh! Will never do that again! Ordered some adapt-cap circuit boards that Bob Anderson uses and decided to re-do them all. Finding bits of solder blobs here and there so could be a short somewhere. Also lots of brittle and cracked cloth covered wire to replace. Looks like I’m in for a lengthy project!