Thanks guys. You've given me plenty to consider.

On another note, recall the label on the CT-100 shows 475 watts at 115 Vac as the power used by a Merrill.

Just measured it. With a 115 Vac line, the unit draws 415 watts with a PF of .85, which measures/calculates out at 485 VA / 488 VA. So in conventional terms the draw is more like 415 watts.