Quote:
Originally Posted by funken
Okay I have a lamp socket. The AC receptacle. Does this mean a wall receptacle?

Do I need to have a spilt power cord from the radio. One wire to the bulb one to the AC?
No, I would not split the actual power cord from the radio, although that would work if you chose to do so.

What I did was buy one of those heavy-duty extension cords (the "orange" 16 gauge outdoor extension cords used usually by electric weed wackers and such). That extension cord gives you both the plug and receptacle. I just split one of the wires (not the 3rd ground wire), and wired the light bulb socket in series with that split wire, as shown in the diagram. I left the other 2 wires (usually called neutral and ground) intact.



Also, follow the directions exactly, including removing your rectifier tube (the #80 tube) before plugging your radio into the test device for the first time. The directions gives you good steps to perform, and what to look out for.

Hope this helps!

Last edited by tomwil; 06-12-2006 at 12:05 AM.