Quote:
Originally Posted by old_coot88
Since you've replaced all the electrolytics (and verified they're all in correct polarity), i would tend to suspect wiring error at this point. Does the schematic show any of the electrolytics "floating" (ie., not connected directly to chassis ground)?
Is this set the RCA 630ts that was having the low B+ issue?
There are a number of good oscilloscope tutorials on Google. But the problem at hand should be easy enuff to resolve without a scope.
|
I tend to think wiring error also, nobody's prefect least of all me

. There are four floating electrolytics and two which are at ground.
This is the 630 with the low B+. I went through section by section and found where it was bogging down and fixed that problem.
I did find some nice tutorials on youtube about scopes. I think I'll keep this set out of the cabinet for a bit after I'm through with her and get some practical experience.