The resistor in parallel (if the peaking coil has one) affects the bandwidth of the peak (or null, if it is used in a trap circuit). The DC resistance of the coil is usually much lower than the parallel resistor, so the resistor value could change a lot and you might not notice the effect. Coil failure hypothetically can be either opening, or shorting of one turn to another.

I think that these low power peaking coils usually fail open due to corrosion over a long period. Coils and transformers that carry high power (like in the deflection circuits) can fail due to heat or arcs causing shorted windings. In this case, the AC operation is ruined, but the DC resistance may not change much, because only one turn is shorted out of tens or hundreds.

Maybe some others can chime in on which types of failures typically occur in different coil applications.
__________________
www.bretl.com
Old TV literature, New York World's Fair, and other miscellany
Reply With Quote
 



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 12:33 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.