#11
|
||||
|
||||
|
R104 has already been replaced from the looks of it. it tested out at 151k
R102 tested at 3.1 meg R103 tested at 2.8 meg They are all seem pretty close to spec. Also noticed C-4 electrolytic has been replaced. Sams shows it as a 50 @ 50v and was replaced with a 47 @ 50v. that is pretty close. not sure if that should get switched out or not. I thought I read something once about its ok to go slightly above but not below spec. but that may have been for the voltage rating now that I think about it more. lol |
|
|