Quote:
Originally Posted by DavGoodlin View Post
That old Stancor looks fantastic for almost any radio, for a TV you need about 300 watts and color TV 400 watts minimum.

I found this Halldorson 500 VA with tap switches. I still use an oversized powerstat that was liberated from a theatrical lighting dimmer, in line before it rather than risk a mechanical failure of the switches, which are buried inside. The meter is pretty worthless accuracy wise.
Attachment 201469
If you have a variac(with voltage step up at the top of it's range) in series you can use an isolation transformer in overload mode for short stints say under 10min. Before I had decent sized isolation I would set my 120V in variacs output close to 140V and drive my isolation transformer off of it for small monochrome TVs and it would be sufficient for quick diagnostic power ups... gotta watch the temp when doing that though. That transformer developed a primary to secondary short after a couple years in service.
__________________
Tom C.

Zenith: The quality stays in EVEN after the name falls off!
What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4
Reply With Quote
Audiokarma
 



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 11:10 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.