Thanks guys. That confirmed what I was thinking, not much else other than the cap and the transformer to go wrong and these caps are reaching their "use-by" dates. But when a new replacement part fails shortly after installation, it usually means you fixed the symptom, not the real fault.
I read that the value of that capacitor on these constant-voltage transformers has to be correct as it forms a 60 Hz tuned circuit with the inductance of the transformer.
I still had the cap I removed from the set. It's a 3.5 uF, 6%, 440 V, but measured 3.99 uF on my DMM. I heated it with my heat gun and it rose up to 4.25 uF. So I think what was happening is that the resonant frequency didn't match the 60 Hz drive frequency, caused higher current thru the cap and transformer, heating it up, going further off resonance resulting in thermal runaway.
I do have one more N.O.S. capacitor to try when I have time to get back in to this set, this one measures 3.3 uF, increasing when heated.
Reply With Quote
 



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 09:13 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.