Refering back to your first post: When you replaced the two voltage double caps in the LV PS (C103 & 104), did you replace with correct 200 uf, or did you put new 80 uf back in?

If your HOT grid bias is too positive, that could be caused by not enough grid drive. Do you have the correct 200 and 270v on the plates of the Horz OSC tube? Does the drive signal amplitude change much with the HOT pulled? How's the voltage on the screen grid of the HOT?