Boy that is one congested piece of test gear.

From what I gather, it sounds like the output level was factory programed to a flat response at the various RF/IF frequencies for each individual VA-62. So any variation at lower IF frequencies is likely coincidental and would need to be programed out via Eprom.

Are you guys pursuing these units to use as an IF marker generator; to be used along with another sweep generator? Or are you planning to use the Sencore multiburst modulation method of IF alignment?

I'm curious just how well the Sencore multiburst alignment method caught on with repair techs? For my hobby use I think I'll prefer to stick with the old tried and true scope method of actually seeing the IF response curve on a scope. I can however see the practicality of the burst method for a busy repair shop.

Last edited by Kevin Kuehn; 03-16-2012 at 11:44 PM. Reason: spelling
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 08:59 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.