Old 07-17-2012, 07:13 PM
DaveWM DaveWM is offline
VideoKarma Member
 
Join Date: Feb 2009
Location: Orlando FL
Posts: 5,607
did you check the screen voltage of the HOT? If you have a good drive signal I would start by subbing in a new HOT/Damper as well. Is the Damper filament staying lit the whole time, I had a bad ground stake that would cause it to go out.
Reply With Quote
  #2  
Old 07-17-2012, 07:20 PM
Down Under's Avatar
Down Under Down Under is offline
VideoKarma Member
 
Join Date: Jul 2012
Location: Melbourne, Australia.
Posts: 145
Quote:
Originally Posted by DaveWM View Post
did you check the screen voltage of the HOT? If you have a good drive signal I would start by subbing in a new HOT/Damper as well. Is the Damper filament staying lit the whole time, I had a bad ground stake that would cause it to go out.
Hi Dave,

I've subbed a new 6DA4 damper, and I've also replaced the sockets of both the HOR out and the Damper tubes. All of the filaments stay lit, but I haven't checked the screen voltage of the HOT. (Just so I know, are you talking HOR out tube, or HOR out transformer?)

I'm assuming you mean the 6DQ6 o/p tube.

Cheers,

Adam
__________________
Four Predictas down, now to score a Continental.
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 04:43 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.