Quote:
Originally Posted by Kevin Kuehn View Post
If it's for shielding, the plate is at higher potential than the grid.
True, the plate is at higher DC potential. But signal wise, the plate presents lower impedance-to-ground than the grid which the cap is coupling to. Ergo, better shielding is obtained with the outside foil connected to the plate.

Last edited by old_coot88; 06-09-2013 at 02:49 PM.