#10
|
||||
|
||||
|
The matrix alignment had me confused at first when looking at the R-Y scope pattern from a color bar generator. I realized the RCA color bar generator color sequence is not the same as my Sencore VA62 color bar sequence. Here is a list of the correspondence:
Pulse after burst---RCA--------------------Sencore VA62 --------1-----------yellow-orange----------green-blue --------2-----------orange------------------cyan --------3-----------red----------------------blue-green --------4-----------blue-red----------------green --------5-----------magenta----------------yellow-orange --------6-----------blue---------------------orange --------7-----------green-blue--------------red --------8-----------cyan---------------------blue-red --------9-----------blue-green--------------magenta --------10----------green-------------------blue (Sorry for the -'s, I don't know how to set up columns) I was able to do the matrix alignment after translating from the RCA to the VA62 color sequence numbers, but it was confusing for me. Last edited by Zenith6S321; 06-16-2013 at 10:02 AM. |