#1
|
||||
|
||||
|
You have a badly misconverged image -the blue lateral is off a bit, but red and green seem converged, giving the yellow lines. The black stuff at the base of the tube is the rtv rubber zenith used to hold the tubes in place for shipping. Dust away the salts and she'll be fine.
Zeno can chime in on this one -I've not worked a Zenith hybrid in a while, as dura module sets are plentiful in my world. Cheers,
__________________
Brian USN RET 22YRS (Avionics/Cal) CET-Consumer Repair and Avionics ('88) "Capacitor Cosmetologist since '79" When fuses go to work, they quit! |
|
#2
|
||||
|
||||
|
Good to see it on the bench.
Minor width problem most likely H. output tube. damper & H. osc tubes also possable and filter can ( in front of tripler ). The CRT looks very strong. Blue lateral is the white part on the neck. Has 2 rings with tabs for purity & the twist magnet is the blue lat. Give that a turn to put the blue on the yellow. Clean tuner & hopefully the snow comes back. Chromatic switch. Note the color, tint, bright & contrast knobs have holes. There is a second set of controls for the chromatic. With it on ( orange ) the regular controls dont work you use the screwdriver to adj it. When off the outside controls work. Color problem. 1) clean normal/align switch on top of chassis between the color module. If that dont work...... 2)remove the 2 color modules ( 9-27 & 9-?? ) if the IC's are still plug in remove them & clean sockets. Be sure to note the markings to put them back in right. Spray the module contacts also. If that dont work...... 3) put on a color picture. Put norm/align switch in align. Adjust the APC control on the 9-27 board for the FEWEST bars rolling through picture. Return to normal. That will keep you busy for a while !! 73 Zeno
|
![]() |
| Thread Tools | |
| Display Modes | |
|
|