No videos ... just numbers!
Try measuring other circuit point voltages. In particular: using an ANALOG voltmeter with a 10 meg resistor between circuit and probe tip, not digital multimeter, OR digital meter with the 10 meg resistor at the probe tip and 1 .01 uF cap from probe tip to ground, measure the following: pins 1 and 3 of V706 (RCA) the 6BN8 phase detector and pin 9 of V707 the 6U8 reactance tube. Have you checked the resistance, disconnected from the circuit, of R727A and R727B, attached to pins 1 and 3 of V706. These REALLY should be within 1% of each other. Try everybody's suggestions and carefully report back. |