I have a Veric, it looks like an isolation transformer is different. Does it some how prevent electrocution when touching the chasse?
|
|
#2
|
|||
|
|||
|
After reading a WIKI on isolation transformers it sounds like something I should integrate into the VARIC box I am building?
|
|
#3
|
||||
|
||||
|
Yes use them together. There are some nice combos but since
they are so useful they are expensive. Example: http://www.ebay.com/itm/SENCORE-PR57...YAAOSwYHxWJCIl If you have spare meters put one in for AC amps 0-5 & one for output AC volts 0-150 Also fuse the output at 5A 73 Zeno ![]() |
|
#4
|
||||
|
||||
|
Quote:
By the way it is spelled Variac and resistor not varic and resister. Technically a Variac is a trade name for a speciffic company's variable auto-transformer, but it has become like Kleenex or Bandaid...Synonymous with the product regardless of the maker.
__________________
Tom C. Zenith: The quality stays in EVEN after the name falls off! What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4 |
|
#5
|
||||
|
||||
|
Never noticed where but I would put the Variac after isolation.
With it you will be safe, can turn it down to break in a set & sniff out weak tubes that wont run on reduced voltage. Monitoring the current is essential for troubleshooting TV Hoz & HV circuits in solid state ( SS ) sets. Going higher is a good test of a SS sets regulator. You can test things that run on 24 VAC or other low AC voltages, just dont bump the knob ! 73 Zeno
|