Quote:
Originally Posted by dieseljeep View Post
The schematic shows 5000pf heater bypass caps in the IF strip. Check for a shorted cap. Also, one of the tubes in the same string may have an H-K short.
The tubes are in a series-parallel arrangement.
I made a mistake on the disc caps. 250pf.
There has to be a fault on tube socket between pins 3&4. Maybe a solder splash or????.
Reply With Quote
  #2  
Old 12-28-2015, 11:43 PM
Kevin Kuehn's Avatar
Kevin Kuehn Kevin Kuehn is offline
Workin' Late Again
 
Join Date: Jan 2011
Location: WI
Posts: 3,976
Sorry, I completely spaced out that it's a series heater string. But that's a weird thing you have going on there.