Focus coil and ion trap adjustment with the set on is sort of mandatory to do it right. It is possible to be zapped any time a TV is on (and sometimes when it's off) if you are careless. Always work with one hand in your pocket when the set is on (it almost guarantees protection from harmful levels of electric shock).

If the CRT is metal cone don't get your hand closer than 3", beware of yoke and H output tube cap voltages while servicing those can be nastier than HV....I've personally been hit by HV and yoke voltage, and found the yoke triggered my reflexes much more violently.

Voltage rating of a cap is the maximum they will take before blowing up, shorting out etc. It's always fine to select a higher voltage cap. Tolerance rating of a cap applies only to the Capacitance (in farads or micro farads) not voltage.
__________________
Tom C.

Zenith: The quality stays in EVEN after the name falls off!
What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 05:58 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.