#31
|
||||
|
||||
|
Just spent 2 hours doing dynamic convergence on the Admiral. It was driving me crazy, so I did the best job I possibly could. It's a ton better than it was. One thing that bothers me though, the CRT tested perfect, but the Sencore CR70 and B&K 470 showed a resistive short (not all the way shorted) on the green G1. I didn't try to repair it since it's working fine.