If both vert and horiz stability are bad, and the caps have been replaced, I'd look for a drifted or open resistor in the sync separator circuit.
Reply With Quote
  #2  
Old 08-20-2017, 04:00 PM
FrankieKat FrankieKat is offline
VideoKarma Member
 
Join Date: Feb 2012
Location: Brooklyn, NY, USA
Posts: 42
Quote:
Originally Posted by Eric H View Post
If both vert and horiz stability are bad, and the caps have been replaced, I'd look for a drifted or open resistor in the sync separator circuit.
I think I figured this one out actually. Turns out the tuning and fine tuning on the same shaft were frozen solid together and didn't even realize there were two. Was finally able to work it free and with the fine tuning dialed in the lock is solid both ways. Now of course, sound is best when tuned away from best picture, but that seems like more of an alignment issue -- problem for another day!

I was noticing the certain voltages were still low, such as the CRT screens and the boost voltage was about 520V where it should be 580. Checking the schematic again I realized there were two caps that I didn't mark as replaced which turned out were in the HV cage (duh). I carefully took it all apart, replaced the caps and carefully put it back together and.... no HV. Took it all the way apart again, triple checked the wiring and joints, carefully put it all back together and... still no HV. Verified DC resistance all the way across the flyback, resistance between the grid caps of horiz output and HV rect were both spot on schematic. Ultimately, it appears that in the jostling around, the filament of the HV rect decided to go open - no continuity between pins 2 and 7. Tried touching up the pins, removed the base and tested directly at the leads, but still open. Unfortunately this is the only tube I do not have a spare of, so at a small pause.

Before all of this I did experiment with the brightener and it did make a difference in terms of overall brightness however the contrast was still very washed out. As in, adjusting brightness/contrast it went from dim gray on gray to saturated white on white. Possible if the caps I did replace could have been causing this? (attaching snippet of schematic)

Thx all!

FK
Attached Images
File Type: jpg west1.jpg (55.2 KB, 27 views)
Reply With Quote
  #3  
Old 08-20-2017, 10:58 PM
FrankieKat FrankieKat is offline
VideoKarma Member
 
Join Date: Feb 2012
Location: Brooklyn, NY, USA
Posts: 42
Well, I've learned that apparently you can't test a 1B3 tube's filaments with an ohmmeter, and apparently my tube tester also cannot test a 1B3 tube so entirely possible that my diagnosis could have been inaccurate.

I went back and did a few more checks and found a few more out of tolerance resistors and one that was open and decided to give it another try. This time, HV did come up briefly but it started arcing after a few seconds. I took the HV cage apart again, even coated the leads of the new caps with corona dope, quadruple checked everything put it back and same thing.

https://youtu.be/mxDbkEfzzWA

The camera doesn't pick it up very well but the buzzing is accompanied by blue-ish flashes in the HV tube. From what I've read, blue means the tube is gassy, but everything was working fine before.

Ideas?

Thanks!

FK
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 07:56 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.