#1
|
||||
|
||||
|
Quote:
You should also see if you have 380vdc on pin 10 of the CRT socket, or if it's easier you can measure under the chassis on the end of R44 which connects to a wire leading up to pin 10 of the CRT socket. This one is also referenced to chassis ground. If those two voltages look good you can proceed to adjusting the location of the ion trap, first try it with the brightness control all the way up. You'll need to move it around the neck as well as fore and aft. Once you get a raster you'll want to turn the brightness down so it's just visible and then find the ion trap's sweet spot that provides the brightest raster. Last edited by Kevin Kuehn; 11-06-2019 at 10:41 PM. |
|
#2
|
|||
|
|||
|
Quote:
Secondly which center terminal is the one for the brightness control? the inner or the outer? |
|
#3
|
||||
|
||||
|
Quote:
Yes it's tough to measure on the CRT connector, which is why I suggested to find the end of R44 which is under the chassis and connected to a wire going up to the CRT socket. |
|
#4
|
|||
|
|||
|
Quote:
Although it makes no difference as I got the measurements I needed, and everything is measuring as it should except for pin 10 of the CRT Socket which is measuring at 404 VDC rather than 380 VDC, but Pin 11 of the CRT Socket (the center tap of the brightness control) is measuring between 15VDC and 140VDC like you said it should when the knob was rotated. So the 404 VDC on pin 10 of the CRT Socket, does that mean something is wrong with that part of the circuit, or is that just because of the higher line voltages? |
|
#5
|
||||
|
||||
|
I think it's close enough. See my previous post about measuring voltage on pin 2 on the CRT socket. If these 3 voltages are in the ball park you should be good to see if you can get a raster by adjusting the ion trap.
|
| Audiokarma |
|
#6
|
||||
|
||||
|
I should have told you to also measure the voltage which goes to pin 2 of the CRT socket referenced to chassis ground, should be 1.3vdc. You can get to that under the chassis on the end R35 that should be connected to another wire going up to pin 2 of the CRT socket. Use the resistor identification on page 17 of your sams to find the actual physical location of the resistors.
|
|
#7
|
|||
|
|||
|
Quote:
So now how do I go about adjusting the Ion Trap on this TV? |
|
#8
|
||||
|
||||
|
Basically you rotate the ion trap magnet, at the same time sliding it back and forth until a raster appears on the screen. For starters turn the brightness up full and dimming the lights will help you catch the location. Once you get a raster you turn the brightness down and fine tune the traps location for brightest raster. Don't panic if you don't find the location right away.