There was a minor problem shown in these pictures, best seen in the one of
the children bearing leaves and the leftmost B&W intensity step pattern. You will note that the left half of the screen was a bit reddish. This was clearly visible with contrast all the way down (which in a CT-100 turns color all the way down too) and brightness way up. (The background in the Christmas picture is supposed to be a yellowish off-white.) It was caused by a modification I made after the first internal arc in the old CRT. I added 100K resistors in series with each CRT screen grid (G2). These are used in all the RCA 21AXP22 and 21CYP22 sets to protect against damage from arcs to or from G2, which is connected to a big fat 80 uF cap. I did not remove them. This allowed capacitative pickup from the multi-hundred-volt dynamic focus and convergence waveforms. It was cured, with no loss to the protective function, by bypassing the three resistors with 1 kV 1nF ceramic caps. P.S. .... the children, of course, were back in 1954 wishing for a CT-100, just like me! Last edited by dtvmcdonald; 11-24-2019 at 09:13 AM. |
![]() |