#1
|
||||
|
||||
|
I remember on early ‘80’s Sony set they had a high voltage shutdown circuit that turn off the set usually caused by the HV resistor in the red epoxy pack causing internally arcing.
__________________
Sony Trinitron is my favorite brand. My wish list: Sony KV-7010U Sony KV-1220U |
|
#2
|
||||
|
||||
|
Good old H-stat control. Did many. For test you can pull off the thin red wire.
Many ran hours without diing or arcing. |
![]() |