#1
|
||||
|
||||
|
50Hz linear power supplies need larger filter and doubler caps than 60Hz supplies do.
There are options for getting 60Hz in 50Hz countries...Perhaps the most straight forward is to buy a US market automotive power inverter (12VDC to 120V 60Hz) off the internet and locally buy a beefy 12V supply....Another option if you know people that work in industrial electronics is to get an old used VFD (variable frequency motor drive) and set its output to 60Hz. Small gasoline generators and dynamotors are also options but probably harder to obtain.
__________________
Tom C. Zenith: The quality stays in EVEN after the name falls off! What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4 |
|
#2
|
||||
|
||||
|
GE sets of this era used to get bad doubler caps. It usually gets extreme
but yours may be just starting. The main filter cans were not a problem on them ( 40 yrs ago !). Since 'lytic cans rarely short try bridging apx 80 mfd across the doubler cap & see if it gets better. Running at 50 cps in theory requires bigger caps but there is some room there. BTW bridging electrolytics is an old trouble shooting technique. It can save you time & $$$. Also give you a look at the pix to see if you want to go further with an old set. BTW2 If you change a doubler cap be SURE you use one rated at the same or higher temp. 73 Zeno ![]() LFOD ! |
![]() |