Yes, I'm pretty sure that's what happened as quite a few caps had puked their guts onto the board which had unfortunately damaged some of the traces, I checked the dioded including the zeners and they all checked as they should thankfully, like I said the only diode that seemed to of failed was the bridge rectifier.
What about the circuit protector PR1 (ICP-F38) in the secondary side across the 5 volt rail? Does it also measure bad (open)?