#1
|
||||
|
||||
|
If you have replaced all the caps in the H sweep circuit it must be something else. I don't know, check caps in horizontal oscillator and amp sections?
Cracked circuit/solder traces taking one of the safety caps out of the circuit? Can you check connectivity from the horizontal output collector to the lead of each safety cap? I was going to suggest looking for a capacitor mounted on the yoke, but I don't see one on the schematic. |
|
#2
|
|||
|
|||
|
I checked the safety caps and they're all in the circuit, they're distributed around the horizontal/HV subchassis and a bad connection would result in other issues. I've replaced almost all of the electrolytic caps in the whole set except for a few that are on the chassis and those test ok in circuit. I don't normally do shotgun re-capping but I was running out of ideas. I wondered if there was a damper resistor somewhere that had opened but I can't see anything on the schematic, I don't see any components on the yoke. I'll keep looking.
|
![]() |
| Thread Tools | |