As far as the tripler in the OP's set, I think that's the one with 5 terminals, and I seem to remember that the ECG sub would not work (it would trip the breaker), and an OEM part may be in order here. I didn't really care for those CC2 sets with the EFL tube. The triplers in those would short the HV to the focus lead and burn up the CRT socket, and in some cases, ruin the tube.
__________________
http://www.youtube.com/user/radiotvphononut |
|
#2
|
|||
|
|||
|
Quote:
Yes, unfortunately it's that 5 terminal one. |
|
#3
|
||||
|
||||
|
#4
|
|||
|
|||
|
Quote:
|
|
#5
|
|||
|
|||
|
Like a nutjob, I snagged what I believe to be the correct paperweight to go with my giant paperweight. Joking aside, I remain committed to finding the tripler and getting this set working again. Here are some pics for the curious. I thought it was kind of funny how the PCB interfaces with the buttons with the same push-on connectors as the modules in the set. I can hear the power button, channel hi, zoom, and volume buttons. My phone registers the tones as being upper 8khz to mid 9khz. The other buttons seem to do something as my mic gets overwhelmed and shows 100db of all frequencies when I hold the remote right up to the mic with buttons pressed. Might be outside the response of the mic. I won't be able to test beyond this till I can power the set up again.
It's half tempting to fire this up again to see if I can witness what exactly went. I hate to break more things. Maybe worth disconnecting the flyback from the tripler to isolate that as being problematic? I have feelers out for a tripler but so far no luck. Side note, I get 10ohms across the oil capacitor, but with it still in circuit. Here, I noticed the ground strap from the aquadag cover (is that what we'd call it?) to the power supply board was baked by an adjacent wire wound resistor. The insulation is crispy now, but I pushed these apart from one another. Guessing this isn't of much consequence, but thought I'd throw that in here. |
| Audiokarma |
|
#6
|
|||
|
|||
|
As an update, I managed to find a NOS ECG561 tripler for a fair price. I still don't even know 100% that is crosses, but the appropriate amount of terminals are there. Do these hold up any better/worse than Zenith parts?
I just applied silicone to the input pin and will wait until tomorrow night to try powering it up. As a side note, I managed to snap in half the clip that covers the focus and control pins when trying to reinstall it. I figure nothing is done without a reason, should I silicone these wires given that the cover broke? |
|
#7
|
|||
|
|||
|
Quote:
__________________
So many projects, so little time... |
|
#8
|
||||
|
||||
|
Zeniths ran somewhere between 30k & 40K. Ultras went away