#1
|
|||
|
|||
|
Emerson tv but what model is it.philco picure tube in it
Testing the picture tube as a 10 bp4 assuming it is a 10bp4 but not sure of model of tv. It has a philco picture tube that I thought was dead no filament light but as I fiddled with the tube socket pins it came on after a good while of me spraying deoxit on pins. Good cutoff and emissions so 50 bucks was worth it. Does say emerson on the chassis sticker and has a few emerson tubes in it so been searching to find one that looks like it so far no go. Allll i seem to find is the emerson 639
Last edited by fumplet; 09-15-2024 at 07:23 PM. |
|
#2
|
||||
|
||||
|
Looks like a 571
|
|
#3
|
||||
|
||||
|
#4
|
|||
|
|||
|
is there supposed to be a cover on top of the high voltage cage? Mine doesnt have a top to it.
Also I noticed that when I measured the filament voltage on the philco picture tube in it, my sencore cr 70 has the red mark for the proper filament voltage of Im guessing 6.3 volts (a/c normally in the set , Not d.c. voltage) I measure 6.14 volts the sencore is supplying so I cranked up the measured with dmm voltage to acutall 6.3 volts although d.c. volts. Is my tester a little low on volts or is it because the measurement is correct because a/c volts is slightly lower for a d.c. equivalent voltage? Last edited by fumplet; 09-16-2024 at 05:51 PM. |
|
#5
|
|||
|
|||
|
already seeing the weird design, theres two can ohm resistors on the high voltage cage along with the big horizontal linearity resistor on the inside. Also the 10bp4 tube has a strange dual ion trap magnet which I assume is still a dual trap one.
Now I really get why you call the circuit design weird. Somebody loved rectifiers a lot. Question is: when one of the 25z5 or was it 6 went out, did that make the other 2 tubes work harder and burn out? [img]http://www.videokarma.org/attachment.php? attachmentid=206870&d=1726666420[/img] Last edited by fumplet; 09-18-2024 at 05:38 PM. |
| Audiokarma |
|
#6
|
||||
|
||||
|
Here's a recent video series I made while restoring one. Emerson 571 restorations: https://www.youtube.com/playlist?lis...GgvlCTnETIpOJK
6.3 volts RMS or 6.3 volts DC. It's not critical. +/- 10% is fine. Don't expect your Sencore analog meter to be perfect unless you've recently calibrated it |
|
#7
|
|||
|
|||
|
Thats the thing id like to open my sencore tester up to see what needs refreshing and or calibrating but i dont even see how it comes apart
Last edited by fumplet; 09-18-2024 at 03:19 PM. |
|
#8
|
|||
|
|||
|
Oh ok i see the hv cover in your video oh welll mines missing
Last edited by fumplet; 09-18-2024 at 03:19 PM. |
![]() |