#2
|
|||
|
|||
|
In almost 50 years, I have encountered two 10BP4s with the same problem; the filament lights, but there is absolutely no emission. Both were from late 1940s sets, so maybe there were some issues during manufacturing.
|
|
#3
|
||||
|
||||
|
Check the cathode connection in the tube. My observation is the cathode opening due to a burst of high current which is enough to melt the fine metal link to the cathode pin of the kinescope.
|
|
#4
|
|||
|
|||
|
I guess a gap of that size means it's hopeless to try to reweld the cathode using that function in many rejuvenators, even with vigorous shocking of the CRT neck?
|
|
#5
|
||||
|
||||
|
Quote:
__________________
Tom C. Zenith: The quality stays in EVEN after the name falls off! What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4 |