#4
|
||||
|
||||
|
First there are 2 versions of the ##EC45 Look for the run ## inked on chassis.
Under run 401 they used 5 identical caps ( part ## 22-5001) from the HOT C to E. NEVER run set with them unhooked. They could open or short. If they are white they HAVE to go. Orange Sprague ones are good. Run ##401 and higher. The 5 caps are gone & replaced with the infamous 4 lead cap. Kit part ## 800-860. Again white ones MUST go, orange are OK. Usually a dead 130 V short gives a loud hum & breaker pop in seconds. An overload gives less hum & a slow breaker pop. Usually its the trippler. Just unhook the input to test. Last thing is the motor cap. They are going left & right now. Usually the sets been restored but it shorts in a few days. To test lift one end & try it. gotta go cook. good luck Zeno ![]() LFOD ! |