I was thinking somewhere between a 50 and 100 ohm 5-watt resistor.
I'm going to go ahead and replace the filter caps (47uf. in place of the 40uf. sections and 100uf. in place of the 80 uf) while I'm in there.
This means I need to make up for three factors that are going to make the B+ higher:
1. diode in place of selenium rectifier
2. higher value filter caps
3. my line voltage is most always 125 to 127 (above what the set was originally rated)
|